Repairs and Planned Maintenance for Large MTU-Engined Sets

We repair, service and maintain large MTU-engined generator sets on site across Gauteng, at data centres, hospitals, mines, factories and large commercial buildings. Most of the work is planned: servicing by hours and time, regular runs under load and small faults fixed before they stop the set. When something does fail, we diagnose it on site and plan the repair around your shutdown window.

  • Established 2006

    20 years of experience

  • 24/7 operations

  • We Arrive Within 1–2 Hours

    (usually within 1 hour)

  • Free callouts and quotations

  • One-year warranty

  • Qualified and certified technicians

  • We Service & Repair All Generator Brands

    All generator makes and models

  • 1 kVA–20,000 kVA capability

Large engines, larger consequences

MTU builds large high-speed diesel engines and is part of Rolls-Royce Power Systems. In generator sets you are most likely to meet the Series 1600, 2000 and 4000 engines. A name such as 16V4000 reads as sixteen cylinders in a V, Series 4000, and the letters and numbers that follow describe the application and rating. Series 1600 and 2000 engines power sets from several hundred kVA to around 1,500 kVA; Series 4000 engines drive the largest sets, past 3,000 kVA at the top of the range.

These engines are turbocharged and charge-air cooled, with electronic engine management. Behind them sit operating theatres, server halls, mine pumping and airport systems, so a failure during an outage costs far more than the repair. The aim is to find faults during planned work, not during load shedding.

Large sites often run several sets, sometimes of different makes: Cummins and Caterpillar engines are common in the same size class. We check the alternator, controller and changeover equipment as well as the engine, because a sound engine is no use if the power cannot reach the load.

What planned maintenance covers on a large MTU set

The engine’s maintenance schedule sets the tasks by hours and time. On a critical site we add the checks that decide whether the set will take the load.
What planned maintenance covers on a large MTU set
SystemTypical checks
LubricationTypical checksOil and filters by hours or time, oil level and leaks, centrifugal or bypass filters where fitted
FuelTypical checksPrimary and secondary filters, water separators, day tank, transfer pumps and bulk tank condition
Air and exhaustTypical checksAir filter restriction, turbocharger condition, charge-air pipework, exhaust leaks and back pressure
CoolingTypical checksCoolant condition and additive, radiator or heat exchanger, fans and belts, jacket water heaters
Engine managementTypical checksLogged faults, sensor readings and protection settings
StartingTypical checksBatteries, chargers and starters (some large engines have two)
Plant roomTypical checksVentilation louvres and dampers, attenuators, fuel and oil containment
LoadTypical checksA run under load to prove the set, on the building load or a load bank

Hours or the calendar: what triggers the service

A prime power set at a mine can run thousands of hours a year and reaches its hour-based service first. A standby set at a hospital or data centre may run only on test, so its time-based tasks come due first, because oil, coolant and fuel age even when the engine barely turns. Load shedding blurs the line: a standby set that runs most days gathers hours like a prime set.
Two examples. A prime power set that runs every day reaches its running-hours interval first. A standby set that only runs on test barely gains hours, so the time interval is reached first. Intervals come from the engine manual, by hours and at least once a year.
Service by running hours or by time, whichever comes first. The principle applies to any large diesel set.Open full size (opens in a new tab)

Risks on large standby sets

What catches large sets out

  • Jacket water heaters: Generator not starting

    Standby engines are kept warm so they can take load quickly. A failed heater or its thermostat means slow, smoky starts and a set that may not take load in time.

  • Light-load running: Wet stacking

    Large engines run on test without load build up carbon and unburnt fuel. Regular runs under real load keep them clean.

  • Fuel storage: Diesel fuel contamination

    Bulk tanks hold fuel for months or years. Water, sludge and microbial growth build up unless the fuel is tested and managed.

  • Plant room ventilation: Overheating

    A large set needs a great deal of cooling air. A louvre or damper that fails to open turns a healthy engine into a high-temperature shutdown.

  • Transfer and synchronising: Control panel repairs

    On multi-set sites the sets must synchronise and share load. A controller, breaker or sensing fault can keep a healthy engine off the busbar.

Site process

How we work on a critical site

Large-site work is planned with the people who run the site, not just the people who own the set.
  1. 01

    Records first

    Engine and set details, running hours, service history and the controller’s event log are recorded, and the scope agreed.

  2. 02

    Permits and a shutdown window

    Inductions, permits to work and the time the set may be out of service are agreed in advance. On multi-set sites, one set is taken out at a time.

  3. 03

    Isolate and work safely

    The set is locked out against automatic starting while it is worked on. No protection is left disabled and nothing is left in manual.

  4. 04

    Prove it under load

    The set is run and loaded, on the building load where the site allows or with a load bank test.

  5. 05

    Hand back in automatic

    The set is returned to automatic, readings are recorded, and anything that needs a further shutdown is listed for planning.

Engine management, sensors and parts

MTU engines rely on electronic engine management for fuelling, speed control and protection. Many faults that look like engine failures are sensor, wiring or supply faults: a chafed harness, a corroded connector or a failing sensor can shut down an otherwise healthy engine. We trace these with the set’s controller, the engine’s own displays and meter checks on the wiring. If a fault needs the engine maker’s own software, we tell you before going further.

Parts are identified from the engine data plate and serial number, which fix the exact build. Filters, belts, hoses, sensors and service parts are genuine or quality-equivalent to the same specification, as the job and the engine allow, and long-lead parts are flagged early so they arrive before the shutdown window. See generator repairs, servicing and maintenance plans for how each visit works.

Independent service

We Service & Repair All Generator Brands

Onsite Generator Repairs is an independent generator specialist. We repair, service and maintain MTU equipment as part of our work on every make of generator.

Manufacturer warranty claims go through the manufacturer’s own network. If your generator is still under warranty, check the warranty terms before arranging work by anyone else.

Brand names and trademarks belong to their respective owners. Onsite Generator Repairs is an independent service and repair company.

Service areas

Where we work in Gauteng

We come to you, wherever the MTU equipment is installed: on-site repairs, servicing and maintenance in all five Gauteng regions.

FAQ

Frequently asked questions

How long can a large standby generator sit without running?

It should be test-run regularly, with periodic runs under load, and serviced by time even when the hours are low. The right routine depends on the engine’s duty and the site, and is agreed as part of a maintenance plan.

What is the difference between standby, prime and continuous ratings?

A standby rating is for mains outages, for limited hours. A prime rating is for sets that are the main power source, running long hours at varying load; a continuous rating is for constant load. The harder the duty, the lower the rating the same engine carries.

Can you load test our MTU set?

Yes. A run under real load is part of planned maintenance on a critical set. Where the building load cannot be used, a load bank test is arranged and quoted, and readings are recorded for comparison year to year.

Do you only work on the engine?

No. We Service & Repair All Generator Brands, and on a large set the alternator, AVR, controller, batteries, fuel system and transfer switchgear are checked on the same visit, because the set only works if all of them do.

What information helps before a visit?

The engine model and serial number, the set rating, recent running hours, any alarms and the date of the last service. For critical sites, tell us about access, inductions and any shutdown windows.